ABOUT US

Page view:
Discharge information:
1, sewage:
Name of discharge port: Xiema crankshaft main discharge port
Emission port number: BBWSG0010201
Discharge direction: Liangtan River
Discharge mode: discontinuous and irregular;
Main pollutants: COD, petroleum, ammonia nitrogen, suspended solids
2. Noise:
Name of main noise source: lathe, grinder
3. Exhaust gas:
No boilers, coal burning, etc., intermittent irregular, high-altitude emissions
II. Basic situation of sewage treatment facilities:
Name: Wastewater treatment method of oily wastewater treatment station: eddy current dissolved air floatation floating method
Design processing capacity (ton/day): 120 facilities original value (10,000 yuan): 67.6 input time: November 2005
Upgrade and transformation time: July 2015 sewage discharge: first-class standard
3. Emergency plans for environmental pollution:
1 Scope
This standard stipulates the emergency measures for environmental pollution accidents in companies.
2 Normative Reference Documents
2.1 Environmental Manual
2.2 Procedures for Emergency Preparedness and Response
2.3 Procedures for Control of Corrective and Preventive Measures
3 responsibilities
3.1 organization
3.1.1 emergency command team
Chairman: Cao Zhengsu, chairman of the company.
B) Vice Chairman: Zhang Yipeng, General Manager, Wu Tai, Chairman of Trade Union
C) Group member: Hu Hao, Deng Shijun, Liu Yongxin, Liu Yingguo, Rujian Xie Dewen, Wu Bin, Ding Jiliang, Song Shiyuan
D) Field command: Zhang Yipeng, Liu Yongxin, Wu Tai
3.1.2 communication group
A) Group Leader: Administration Department of Huhao Company (tel: 023-68242285)
B) Team member: Tan Xincao Zhengming and Liu Ying
3.1.3 Head of Emergency Team: Deng Shijun, Song Shiyuan
3.1.4 Team Leader: Liu Mingshu Wu Xiaoyu
4 key environmental protection parts
4.1 Leakage of Industrial Oily Wastewater in Workshops
4.2 Oil Leakage, Explosion and Combustion in Workshops
4.3 Company Oily Wastewater Treatment Station
5 disposal after report
5.1 Report
5.1.1 Once an environmental accident occurs in the production workshops and departments of the company, the personnel present shall notify the company's leadership and the safety and environmental protection department of the report as soon as they discover it.
5.1.2 Leakage of oily wastewater. The Section of Safety and Environmental Protection reports to the District Environmental Protection Bureau within one hour.
5.1.3 Oil leakage, the Section of Safety and Environmental Protection reports to the District Environmental Protection Bureau within one hour. If there is oil explosion and burning, the people present immediately evacuate the scene, dial "119", and report to the District Environmental Protection Bureau at the same time.
5.2 Processing after receiving reports
After receiving the report, any member or other person of the company's emergency command team should timely understand the basic situation of environmental accidents and promptly issue effective initial rescue work.
5.2.1 Once the leakage of industrial oily wastewater and oil occurs, the polluted areas should be cleaned up in time. Fire-fighting measures should be formulated according to production conditions, fire-fighting organizations should be set up, and the effect of implementation should be recorded. Fire-fighting equipment should be reasonably equipped according to different operating conditions, and special person on-site monitoring should be set up. When the production height of the production building exceeds 30 meters, it should be equipped with sufficient fire water source and self-saving water consumption, and each floor should be equipped with fire water source interface. And pull a good cordon.
5.2.2 Fireworks are strictly forbidden for inflammable and explosive dangerous goods. They should be classified, stacked and named. Flammable and explosive articles irradiated by the sun should not be stored in the open air; fire signs should be set inside and outside the warehouse, and fire passages not less than 3.5 meters wide should be set aside outside the warehouse. Combining with the nature of the stored articles, corresponding fire fighting equipment should be used.
5.2.3 Warehouses or places for storing inflammable and explosive liquid (gas) or dangerous chemicals shall be equipped with flameproof facilities in accordance with the provisions of the State; various sources of fire shall be strictly controlled; if there are oil tanks around the fire, they can not be eliminated in time (referring to substances that can not be quickly extinguished or easily evacuated), then the adjacent oil tanks shall be cooled to prevent temperature. High explosion; equipped with proper fire extinguishing equipment, gas masks, responsible for management, to ensure that they can be used effectively at any time.
5.2.4 After the explosion and deflagration accident, the emergency team should be dispatched in time to cooperate with the fire brigade, evacuate inflammable and explosive materials to safe places in time, apply fire fighting equipment and tools to extinguish, and set up warning signs for special guardianship. At the same time, the burned personnel should be quickly removed from the fire source, the burning clothes should be cut off, effective measures should be taken to prevent shock, asphyxia, trauma pollution, and painkillers should be used when necessary, and dilute saline should be drank. In addition to chemical burns at the scene, the wound is generally not treated, blisters can not be scratched, covered with clean clothes, the seriously injured are sent to the hospital in time for treatment.
5.2.5 Leakages occurring in the procurement, transportation, storage and distribution of oils and chemicals and in the use of machinery and equipment shall be cleaned up by the material and equipment department. Send a special person to check and repair the water pipeline and eliminate the hidden danger of accidents. Once leakage occurs, the main valve should be closed in time, and the leakage should be dredged into other drainage pipelines. At the same time, emergency personnel should repair the leakage pipeline to eliminate the danger.
5.2.6 After the breakdown of the sewage pipeline, the sewage overflowing the ground is dredged so that it can enter other sewage pipelines. It is strictly forbidden to overflow the sewage and cause environmental pollution. At the same time, it reports that the municipal management and maintenance department sends personnel to carry out timely maintenance.
5.2.7 Duty system should be implemented during company holidays.
6. Organizational measures for emergency evacuation
6.1 After the environmental accident, the company's